Error codes of fiscal drives of cash registers. The codes do not depend on the CCP and will be the same at the box office of any manufacturer and model.
Code
|
Description
|
Details
|
210 | Error of exchange with FN at the interface level | KKT cannot find the fiscal accumulator. Either it does not exist or there is poor contact in the connectors of the connections, or the PV is out of order. |
211 | FN transmission format error | An error can occur if the FN is not fiscalized or the FN archive is closed. It is also possible in case of a malfunction of the fiscal drive. |
212 | Invalid FN state | May occur when performing an operation that is impossible in the current state of the FN. For example, when you try to close a shift if it is not open. Including, perform any operation if the CCP is not registered. In some cases, it may be solved by restarting the CCP. |
213 | Fatal FN error | If turning off the CCP for a while does not help, you need to change the fiscal accumulator, after closing its archive. |
214 | FN checksum error | If turning off the CCP for a while does not help, you need to change the fiscal accumulator, after closing its archive. |
215 | End of life FN | The fiscal accumulator has expired. Close archive and replace. |
216 | FN archive is full | FN memory is full. Close archive and replace. |
217 | Incorrect date and time passed to FN | In the cash register, the date / time is set less than the date / time of the last document in the FN in the current shift. Or more than 24 hours from the opening of the shift. |
218 | No requested data in FN | The requested document was not found in the memory of the fiscal accumulator. |
219 | FN overflow (check total) | FN memory is full. Close archive and replace. |
225 | Invalid FN number | The real number of the FN does not match the number stored in the memory of the CCP. |
231 | Incorrect value of the parameters of the FN command | May occur if the taxation system does not correspond to the specified taxation system. If the general taxation system is used, then the tax liability for 36 months can be used only for the sale of services. |
232 | Excessive size of FN data transmitted in TLV (tag-length-value) format | Occurs if there are too many positions in the check. The data packet transmitted to the FN should not exceed 32768 bytes. |
233 | No transport connection FN | No connection to Fiscal Data Operator (FDO) |
234 | FN cryptographic coprocessor resource exhausted | The fiscal accumulator has expired. Close archive and replace. |
235 | FN storage resource exhausted | The CCP has not sent receipts to the OFD for more than 30 days. Connect with the OFD. |
236 | Message from FDO cannot be accepted by FN | Perhaps the CRF parameters are incorrectly specified in the checkout settings |
237 | FN has unsent fiscal documents | Check the connection to the OFD |
238 | Returning this code means that you can get extended error information with the read register 55 command |